BEST

LSbio ▼Human IDO1 / IDO ELISA Kit (Sandwich ELISA) - LS-F31887

LSbio ▼Human IDO1 / IDO ELISA Kit (Sandwich ELISA) - LS-F31887

브랜드 LSbio
품명 Human IDO1 / IDO ELISA Kit (Sandwich ELISA) - LS-F31887
CAT. NO LS-F31887-1 분류
규격 1 plate 재고 -
소비자가(₩) CAS. NO
온도 위험물
수입발주일 매주 목요일 오후 5시
주의사항
Type
 
Sandwich ELISA (enzyme-linked immunosorbent assay) kit
Target
 
IDO1 / IDO
Reactivity
 
Human
Manual
 
Intended Sample Types
 
Plasma, Serum, Tissue Homogenates
Format
 
96-Well Strip Plate
Detection
 
Colorimetric - 450nm (TMB)
Measurement
 
Quantitative
Detection Range
 
0.156 - 10 ng/ml
Sensitivity
 
0.094 ng/ml
Precision
 
Intra-Assay: CV<8% Inter-Assay: CV<10%
Storage
 
Store at 4°C. Stable for 6 months.
Quality Assurance
 
Due to their limited shelf life, LSBio ELISA kits are not typically stocked as finished goods. Upon receipt of an order each kit is assembled and tested to ensure that it meets specifications before shipping. Minor changes may occur to the Range, Sensitivity, and Precision. In the event of a significant change the order would be confirmed with the customer before shipping ELISA kit lot numbers reflect the date of final assembly and testing for each specific kit rather than a bulk manufactured lot. All kits are tested to confirm that they fall within their defined Inter- and Intra- assay coefficient of variation.
Kit Components
 
  • User Manual
  • 96-well Microplate
  • Detection Reagents
  • Wash Buffer
  • Substrate
  • Stop Solution
  • Adhesive Plate Sealers
Background
 
This kit was based on sandwich enzyme-linked immune-sorbent assay technology. Anti- IDO1 antibody was pre-coated onto 96-well plates. And the biotin conjugated anti-IDO1 antibody was used as detection antibodies. The standards, test samples and biotin conjugated detection antibody were added to the wells subsequently, and wash with wash buffer. HRP-Streptavidin was added and unbound conjugates were washed away with wash buffer. TMB substrates were used to visualize HRP enzymatic reaction. TMB was catalyzed by HRP to produce a blue color product that changed into yellow after adding acidic stop solution. The density of yellow is proportional to the IDO1 amount of sample captured in plate. Read the O.D. absorbance at 450nm in a microplate reader, and then the concentration of IDO1 can be calculated.
Restrictions
 
For research use only.
About IDO1 / IDO
 
P14902  NM_002164 AAA36081.1

 

물품 이상, 파손의 경우 제품 수령 후 24시간 내에 연락 주시기 바랍니다.
교환과 반품은 물품 수령 후 2주일 이내에 가능합니다. 단, 수입발주 품목은 교환/반품이 불가합니다.
자세한 사항에 대해서는 동인바이오텍 대표번호 (02-431-7375)로 연락 주시기 바랍니다.